What a spray booth heater does
A spray booth heater is an air makeup unit that heats the outside air drawn into a paint booth to replace the air the exhaust fan removes. A booth exhausts thousands of cubic feet of air every minute to carry overspray away from the painter. That air has to be replaced, and in cold weather the replacement air must be heated or the booth drops toward the outdoor temperature.
Temperature matters to the finish. Many coatings need around 70 ± 2°F, and cold or unstable air causes orange peel, blushing and rework. A correctly sized heater holds the booth at painting temperature all year, and a heater with flash and cure modes also shortens the time between coats and before delivery.
Direct fired vs indirect fired
A direct fired heater puts the burner in the airstream, so nearly all of the fuel's heat goes into the supply air. An indirect fired heater heats the air through a heat exchanger and vents combustion products out a flue. Direct firing is the common choice for heating the large volumes of 100% outside air a spray booth uses. Rammstein Air's gas spray booth heaters are direct fired.
| Direct fired | Indirect fired | |
|---|---|---|
| How air is heated | Burner flame sits in the supply airstream | Burner heats a heat exchanger; air passes over the outside of it |
| Combustion products | Mix into the heated supply air (CO₂, water vapor and trace CO) | Kept separate and vented out through a flue |
| Where the fuel's heat goes | Nearly all of it into the supply air | Part of it leaves with the flue gas |
| Flue / venting | None | Required |
| Typical spray booth use | Heating large volumes of 100% outside makeup air | Where combustion products must stay out of the supply air |
Which heater type an installation may use, and how much air it may recirculate, is set by the applicable equipment standards and your local authority having jurisdiction.
Gas, low NOx or electric
The right heat source depends on the job the heater has to do and what your site and air district allow.
| Option | Best for | Range |
|---|---|---|
| Gas heater / air makeup unit | Heating 100% outside air for the booth exhaust | 400,000 Btu to 5.5 MBtu; 4,000 to 110,000 cfm |
| Low NOx heater | Districts that limit burner NOx, such as SCAQMD | 700,000 Btu ETL listed; larger built to order |
| Electric heater | Adding heat to a non-heated booth, no gas service | 30 kW standard; about 50°F rise |
For waterborne paint, air movement matters as much as heat. A convection drying system blows turbulent air across the panels to speed evaporation, in heated or non-heated booths.
How to size the heater
Heat load in BTU/hr is roughly the booth airflow in cfm × 1.08 × the temperature rise needed on your coldest design day. A 14 × 9 ft booth at 100 fpm moves 12,600 cfm. Heated from 0°F to 70°F, it needs about 953,000 BTU/hr. The burner is then chosen above that figure for margin.
The 1.08 factor is 60 min/hr × 0.075 lb/ft³ × 0.24 Btu/lb·°F, which assumes standard air near sea level. Air is thinner at elevation, so the same cfm carries less heat and high-altitude sites need altitude-specific sizing. Run your own numbers in our spray booth heat load calculator, which corrects for elevation.
What drives operating cost
The biggest lever on a booth's heating bill is how much air the heater has to heat, and for how long. Prep, spray, flash and cure each need different airflow. Heating the maximum volume all day wastes fuel during the stages when no one is spraying.
Airflow (cfm)
Heat load rises in direct proportion to the volume of air you heat. Every cfm you don't need to heat is fuel you don't buy.
Temperature rise
Colder climates need a bigger rise from outdoor air to booth temperature, so the same booth costs more to run in Minnesota than in Texas.
Hours and cycles
Spray, flash and cure time per day, and how many days a year the heater runs.
Fuel price
Natural gas, propane or electricity rates at your site.
Airflow control
A constant air flow heater heats the maximum volume all day. Variable air flow and recirculation cut the volume during flash and cure.
See the five-year operating cost example for a 12,000 cfm automotive booth, and how variable air flow works.
Buyer's checklist
Have these answers ready before you compare quotes:
- Booth size and design airflow (cfm), or booth dimensions and air velocity
- Facility city, state and elevation
- Coldest expected outdoor temperature and target booth temperature
- Available utilities: natural gas, propane or electric service
- Local air district rules on burner NOx emissions
- Indoor, outdoor or rooftop mounting, horizontal or vertical
- New booth or retrofit, single booth or multi-booth
- Control panel: listing (UL 508A), modes, interlocks, VFD
- Listings your inspector expects, such as ETL
- Code path with your local authority having jurisdiction (NFPA 33, NFPA 86)
Glossary
- Air makeup unit (AMU)
- A heater that supplies conditioned outside air to replace air exhausted from a building or booth. Also called a makeup air unit or replacement air unit.
- cfm
- Cubic feet per minute, the volume of air a fan moves. Booth airflow is roughly booth cross-section area × air velocity in feet per minute.
- ΔT (temperature rise)
- The difference between the incoming outdoor air temperature and the temperature you want in the booth.
- Design day
- The cold outdoor temperature a heater is sized for, based on local climate data.
- Direct fired
- A heater whose burner fires directly into the airstream it heats, with no heat exchanger or flue.
- Indirect fired
- A heater that transfers heat through a heat exchanger and vents combustion products through a flue.
- Variable air flow
- Changing fan speed and airflow for each stage of the paint cycle instead of running one fixed volume.
- VFD
- Variable frequency drive. Controls motor speed, and therefore fan airflow.
- Recirculation
- Reusing already-heated booth air during stages when no one is spraying, such as flash and cure.
- Flash-off
- The time between coats for solvent or water to evaporate from the paint film.
- NOx
- Nitrogen oxides formed during combustion. Some air districts limit how much a burner may emit.
- AHJ
- Authority having jurisdiction: the local fire marshal, building official or inspector who approves the installation.
- ETL listed
- Tested and listed by Intertek to the applicable safety standard. A listed system is easier to permit and inspect.
- UL 508A
- The standard for industrial control panels.